← Back to catalogue

Measurement & testing
Price on request
Request a quote →
DKG-21 EcotestCARD
Personal gamma radiation dosimeter
EcotestCARD is a direct reading personal dosimeter for personnel exposure monitoring.
Features
- Storage of dose accumulation history in the non-volatile memory with real-time reference
- Transfer of dose accumulation history through the infrared port to the computer
- Blocking the mode of power supply switch off until the data reading procedure finished
- Gamma and X-ray radiation DER and DE threshold levels programming with the help of the computer or manually with control keys
- Blocking certain indication modes in response to the computer command
- Light and audio alarms when programmed threshold levels exceeded on DER and DE of gamma and X-ray radiation
- Display automatic switch off if current gamma background is lower than the preset threshold level with instant switching on at:
- – pressing any control key
- – gamma background increase above the preset threshold level
- – alarm clock ringing
- Periodic self-testing of batteries and detector
- Energy-compensated Geiger-Muller counter
- Ingress protection rating IP31
- Clock, alarm clock
- Software allows to:
- – program parameters and operating modes
- – read dosimetric measurement results
- – review and print dosimetric information as reports
- – save and export read information as a report or text file for further processing by other text editors
- – import previously stored dosimetric information for processing and analysis
Purpose of Use
- Measurement of individual dose equivalent (DE) of gamma and X-ray radiation
- Measurement of individual dose equivalent rate (DER) of gamma and X-ray radiation
Description
- This dosimeter badge can be used either independently or within the automated system of personal dosimetry control.
- In 2011, the Ministry of Emergency Situations of Ukraine sent EcotestCARD dosimeters to Japan as humanitarian aid for recovery from the accident at the Fukushima NPP, where they gained a reputation of a reliable and precise product.
Delivery Kit
- personal gamma radiation dosimeter
- charger
- operating manual
- case with a clip
- package
Specifications
| Measurement range of gamma radiation individual dose equivalent rate (DER) | 1·10⁻⁷ … 1 Sv/h |
|---|---|
| Main relative permissible error limit when measuring gamma radiation DER at ¹³⁷Cs calibration with a confidence probability of 0.95: | |
| – in the range from 1·10⁻⁶ Sv/h to 1·10⁻⁵ Sv/h (inclusive) | 20 % |
| – in the range from 1·10⁻⁵ Sv/h to 1 Sv/h | 15 % |
| Measurement range of gamma radiation individual dose equivalent (DE) | 1·10⁻⁶ … 9.999 Sv |
| Main relative permissible error limit of gamma radiation DE measurement with confidence probability of 0.95 | 15 % |
| Energy range of detected gamma radiation | 0.05 … 6 MeV |
| Energy dependence when measuring gamma radiation DER and DE relative to 0.662 MeV energy (¹³⁷Cs) in the energy range from 0.05 to 1.25 MeV, not more | ±25 % |
| Complementary relative permissible error limit of photon-ionizing radiation DER and DE measurement result caused by ambient temperature deviation from 20 °С, in the temperature range from -20 to +50 °С | 5 % per each 10 °C of deviation from 20 °C |
| Battery life (under gamma background not more than 0.5 µSv/h, switched off alarm system and display) | 800 hours |
| Operating supply voltage of the dosimeter from EEMB battery (LIR2450) | 3.7 V |
| Operating temperature range | -20 … +50 °C |
| Dimensions | 90 × 55 × 10 mm |
| Weight | 0.08 kg |